diff options
author | Edward O'Callaghan <eocallaghan@alterapraxis.com> | 2014-03-13 01:08:31 +1100 |
---|---|---|
committer | Kyösti Mälkki <kyosti.malkki@gmail.com> | 2014-03-13 20:25:22 +0100 |
commit | 236cf4751345da3748cfcaa9f8c8a73889415ab3 (patch) | |
tree | 5ec2d836ca46013abca519ae6dd760388f603b3b | |
parent | a31ff73e8de60ca6ac61a724f8c7649a1034176f (diff) | |
download | coreboot-236cf4751345da3748cfcaa9f8c8a73889415ab3.tar.xz |
mainboard/jetway/nf81-t56n-lf: Remove hard-coded IMC fan craft.
Fan controls in 0x400-0x4ff are not programmed here. Thus fan
control from amd/persimmon in the devicetree.cb does not apply
to this board.
Change-Id: I9156143476df0a7b44c7af90fa2107e8a8ba851e
Signed-off-by: Edward O'Callaghan <eocallaghan@alterapraxis.com>
Reviewed-on: http://review.coreboot.org/5381
Tested-by: build bot (Jenkins)
Reviewed-by: Kyösti Mälkki <kyosti.malkki@gmail.com>
-rw-r--r-- | src/mainboard/jetway/nf81-t56n-lf/devicetree.cb | 49 |
1 files changed, 0 insertions, 49 deletions
diff --git a/src/mainboard/jetway/nf81-t56n-lf/devicetree.cb b/src/mainboard/jetway/nf81-t56n-lf/devicetree.cb index 1e9c95b519..99b226625f 100644 --- a/src/mainboard/jetway/nf81-t56n-lf/devicetree.cb +++ b/src/mainboard/jetway/nf81-t56n-lf/devicetree.cb @@ -108,55 +108,6 @@ chip northbridge/amd/agesa/family14/root_complex register "gpp_configuration" = "4" # GPP_CFGMODE_X1111 - PortA-D on 15.0-3 are each x1 lanes. register "boot_switch_sata_ide" = "0" # 0: boot from SATA. 1: IDE - # Set up SB800 Fan control registers and IMC fan controls - # TODO: verify SB handles the HW monitor and not the super io (PME) - register "imc_port_address" = "0x6E" # 0x2E and 0x6E are common - register "fan0_enabled" = "1" - register "fan1_enabled" = "1" - register "imc_fan_zone0_enabled" = "1" - register "imc_fan_zone1_enabled" = "1" - - register "fan0_config_vals" = "{ \ - FAN_INPUT_INTERNAL_DIODE, FAN_POLARITY_HIGH, \ - FREQ_25KHZ, 0x08, 0x00, 0x00, 0x00, 0x00,\ - 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00 }" - register "fan1_config_vals" = "{ \ - FAN_INPUT_INTERNAL_DIODE, FAN_POLARITY_HIGH, \ - FREQ_25KHZ, 0x10, 0x00, 0x00, 0x00, 0x00, \ - 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00 }" - - register "imc_zone0_mode1" = " \ - IMC_MODE1_FAN_ENABLED | IMC_MODE1_FAN_IMC_CONTROLLED | \ - IMC_MODE1_FAN_STEP_MODE | IMC_MODE1_FANOUT0" - register "imc_zone0_mode2" = " IMC_MODE2_TEMPIN_SB_TSI | \ - IMC_MODE2_FANIN0 | IMC_MODE2_TEMP_AVERAGING_DISABLED" - register "imc_zone0_temp_offset" = "0x00" # No temp offset - register "imc_zone0_hysteresis" = "0x05" # Degrees C Hysteresis - register "imc_zone0_smbus_addr" = "0x98" # Temp Sensor SMBus address - register "imc_zone0_smbus_num" = "IMC_TEMP_SENSOR_ON_SMBUS_3" # SMBUS number - register "imc_zone0_pwm_step" = "0x01" # Fan PWM stepping rate - register "imc_zone0_ramping" = "0x00" # Disable Fan PWM ramping and stepping - - register "imc_zone1_mode1" = " \ - IMC_MODE1_FAN_ENABLED | IMC_MODE1_FAN_IMC_CONTROLLED | \ - IMC_MODE1_FAN_STEP_MODE | IMC_MODE1_FANOUT1" - register "imc_zone1_mode2" = " IMC_MODE2_TEMPIN_SB_TSI | \ - IMC_MODE2_FANIN1 | IMC_MODE2_TEMP_AVERAGING_DISABLED" - register "imc_zone1_temp_offset" = "0x00" # No temp offset - register "imc_zone1_hysteresis" = "0x05" # Degrees C Hysteresis - register "imc_zone1_smbus_addr" = "0x98" # Temp Sensor SMBus address - register "imc_zone1_smbus_num" = "IMC_TEMP_SENSOR_ON_SMBUS_3" # SMBUS number - register "imc_zone1_pwm_step" = "0x01" # Fan PWM stepping rate - register "imc_zone1_ramping" = "0x00" # Disable Fan PWM ramping and stepping - - # T56N has a Maximum operating temperature of 90C - # ZONEX_THRESHOLDS - _AC0 - _AC7, _CRT - Temp Threshold in degrees C - # ZONEX_FANSPEEDS - Fan speeds as a "percentage" - register "imc_zone0_thresholds" = "{ 87, 82, 77, 72, 65, 1, 0, 0, 90 }" - register "imc_zone0_fanspeeds" = "{100, 7, 5, 4, 3, 2, 0, 0 }" - register "imc_zone1_thresholds" = "{ 85, 80, 75, 65, 1, 0, 0, 0, 90 }" - register "imc_zone1_fanspeeds" = "{100, 10, 6, 4, 3, 0, 0, 0 }" - end #southbridge/amd/cimx/sb800 # end # device pci 18.0 # These seem unnecessary |