google/grunt: fix thermal zone CPU temperature report
there are 3 thermal sensors and index is: 0: 1 Charger 1: 1 SOC 2: 0 CPU it needs to adjust sensor to index 2 to have correct CPU temperature. BUG=b:111284412 BRANCH=master TEST=emerge-grunt coreboot Change-Id: I27afb6c5b64b0c39d6db15e6c61ea16a1fda1ca3 Signed-off-by: Kevin Chiu <Kevin.Chiu@quantatw.com> Reviewed-on: https://review.coreboot.org/27469 Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Paul Menzel <paulepanter@users.sourceforge.net> Reviewed-by: Martin Roth <martinroth@google.com>
-rw-r--r--src/mainboard/google/kahlee/variants/careena/include/variant/thermal.h2
-rw-r--r--src/mainboard/google/kahlee/variants/grunt/include/variant/thermal.h2
2 files changed, 2 insertions, 2 deletions
diff --git a/src/mainboard/google/kahlee/variants/careena/include/variant/thermal.h b/src/mainboard/google/kahlee/variants/careena/include/variant/thermal.h
index 2c983bb738..1bb78efa2a 100644
--- a/src/mainboard/google/kahlee/variants/careena/include/variant/thermal.h
+++ b/src/mainboard/google/kahlee/variants/careena/include/variant/thermal.h
@@ -27,7 +27,7 @@
*/
/* Control TDP Settings */
-#define CTL_TDP_SENSOR_ID 0 /* EC TIN0 */
+#define CTL_TDP_SENSOR_ID 2 /* EC TIN2 */
/* Temperature which OS will shutdown at */
#define CRITICAL_TEMPERATURE 94
diff --git a/src/mainboard/google/kahlee/variants/grunt/include/variant/thermal.h b/src/mainboard/google/kahlee/variants/grunt/include/variant/thermal.h
index 2c983bb738..1bb78efa2a 100644
--- a/src/mainboard/google/kahlee/variants/grunt/include/variant/thermal.h
+++ b/src/mainboard/google/kahlee/variants/grunt/include/variant/thermal.h
@@ -27,7 +27,7 @@
*/
/* Control TDP Settings */
-#define CTL_TDP_SENSOR_ID 0 /* EC TIN0 */
+#define CTL_TDP_SENSOR_ID 2 /* EC TIN2 */
/* Temperature which OS will shutdown at */
#define CRITICAL_TEMPERATURE 94