diff --git a/src/mainboard/asrock/imb-a180/BiosCallOuts.c b/src/mainboard/asrock/imb-a180/BiosCallOuts.c
index 37b175cccc..9c316bdfe5 100644
--- a/src/mainboard/asrock/imb-a180/BiosCallOuts.c
+++ b/src/mainboard/asrock/imb-a180/BiosCallOuts.c
@@ -110,184 +110,6 @@ static const CODEC_TBL_LIST CodecTableList[] =
{(UINT32)0x0FFFFFFFF, (CODEC_ENTRY*)0x0FFFFFFFFUL}
};
-#define FAN_INPUT_INTERNAL_DIODE 0
-#define FAN_INPUT_TEMP0 1
-#define FAN_INPUT_TEMP1 2
-#define FAN_INPUT_TEMP2 3
-#define FAN_INPUT_TEMP3 4
-#define FAN_INPUT_TEMP0_FILTER 5
-#define FAN_INPUT_ZERO 6
-#define FAN_INPUT_DISABLED 7
-
-#define FAN_AUTOMODE (1 << 0)
-#define FAN_LINEARMODE (1 << 1)
-#define FAN_STEPMODE ~(1 << 1)
-#define FAN_POLARITY_HIGH (1 << 2)
-#define FAN_POLARITY_LOW ~(1 << 2)
-
-/* Normally, 4-wire fan runs at 25KHz and 3-wire fan runs at 100Hz */
-#define FREQ_28KHZ 0x0
-#define FREQ_25KHZ 0x1
-#define FREQ_23KHZ 0x2
-#define FREQ_21KHZ 0x3
-#define FREQ_29KHZ 0x4
-#define FREQ_18KHZ 0x5
-#define FREQ_100HZ 0xF7
-#define FREQ_87HZ 0xF8
-#define FREQ_58HZ 0xF9
-#define FREQ_44HZ 0xFA
-#define FREQ_35HZ 0xFB
-#define FREQ_29HZ 0xFC
-#define FREQ_22HZ 0xFD
-#define FREQ_14HZ 0xFE
-#define FREQ_11HZ 0xFF
-
-/* imb_a180 Hardware Monitor Fan Control
- * Hardware limitation:
- * HWM failed to read the input temperture vi I2C,
- * if other software switch the I2C switch by mistake or intention.
- * We recommend to using IMC to control Fans, instead of HWM.
- */
-#if 0
-static void oem_fan_control(FCH_DATA_BLOCK *FchParams)
-{
- FCH_HWM_FAN_CTR oem_factl[5] = {
- /* temperature input, fan mode, frequency, low_duty, med_duty, multiplier, lowtemp, medtemp, hightemp, LinearRange, LinearHoldCount */
- /* imb_a180 FanOUT0 Fan header J32 */
- {FAN_INPUT_INTERNAL_DIODE, (FAN_STEPMODE | FAN_POLARITY_HIGH), FREQ_100HZ, 40, 60, 0, 40, 65, 85, 0, 0},
- /* imb_a180 FanOUT1 Fan header J31*/
- {FAN_INPUT_INTERNAL_DIODE, (FAN_STEPMODE | FAN_POLARITY_HIGH), FREQ_100HZ, 40, 60, 0, 40, 65, 85, 0, 0},
- {FAN_INPUT_INTERNAL_DIODE, (FAN_STEPMODE | FAN_POLARITY_HIGH), FREQ_100HZ, 40, 60, 0, 40, 65, 85, 0, 0},
- {FAN_INPUT_INTERNAL_DIODE, (FAN_STEPMODE | FAN_POLARITY_HIGH), FREQ_100HZ, 40, 60, 0, 40, 65, 85, 0, 0},
- {FAN_INPUT_INTERNAL_DIODE, (FAN_STEPMODE | FAN_POLARITY_HIGH), FREQ_100HZ, 40, 60, 0, 40, 65, 85, 0, 0},
- };
- LibAmdMemCopy ((VOID *)(FchParams->Hwm.HwmFanControl), &oem_factl, (sizeof(FCH_HWM_FAN_CTR) * 5), FchParams->StdHeader);
-
- /* Enable IMC fan control. the recommand way */
- if (IS_ENABLED(CONFIG_HUDSON_IMC_FWM)) {
- /* HwMonitorEnable = TRUE && HwmFchtsiAutoOpll ==FALSE to call FchECfancontrolservice */
- FchParams->Hwm.HwMonitorEnable = TRUE;
- FchParams->Hwm.HwmFchtsiAutoPoll = FALSE;/* 0 disable, 1 enable TSI Auto Polling */
-
- FchParams->Imc.ImcEnable = TRUE;
- FchParams->Hwm.HwmControl = 1; /* 1 IMC, 0 HWM */
- FchParams->Imc.ImcEnableOverWrite = 1; /* 2 disable IMC , 1 enable IMC, 0 following hw strap setting */
-
- LibAmdMemFill(&(FchParams->Imc.EcStruct), 0, sizeof(FCH_EC), FchParams->StdHeader);
-
- /* Thermal Zone Parameter */
- FchParams->Imc.EcStruct.MsgFun81Zone0MsgReg0 = 0x00;
- FchParams->Imc.EcStruct.MsgFun81Zone0MsgReg1 = 0x00; /* Zone */
- FchParams->Imc.EcStruct.MsgFun81Zone0MsgReg2 = 0x00; //BIT0 | BIT2 | BIT5;
- FchParams->Imc.EcStruct.MsgFun81Zone0MsgReg3 = 0x00;//6 | BIT3;
- FchParams->Imc.EcStruct.MsgFun81Zone0MsgReg4 = 0x00;
- FchParams->Imc.EcStruct.MsgFun81Zone0MsgReg5 = 0x00;
- FchParams->Imc.EcStruct.MsgFun81Zone0MsgReg6 = 0x98; /* SMBUS Address for SMBUS based temperature sensor such as SB-TSI and ADM1032 */
- FchParams->Imc.EcStruct.MsgFun81Zone0MsgReg7 = 2;
- FchParams->Imc.EcStruct.MsgFun81Zone0MsgReg8 = 0; /* PWM steping rate in unit of PWM level percentage */
- FchParams->Imc.EcStruct.MsgFun81Zone0MsgReg9 = 0;
-
- /* IMC Fan Policy temperature thresholds */
- FchParams->Imc.EcStruct.MsgFun83Zone0MsgReg0 = 0x00;
- FchParams->Imc.EcStruct.MsgFun83Zone0MsgReg1 = 0x00; /* Zone */
- FchParams->Imc.EcStruct.MsgFun83Zone0MsgReg2 = 0;///80; /*AC0 threshold in Celsius */
- FchParams->Imc.EcStruct.MsgFun83Zone0MsgReg3 = 0; /*AC1 threshold in Celsius */
- FchParams->Imc.EcStruct.MsgFun83Zone0MsgReg4 = 0; /*AC2 threshold in Celsius */
- FchParams->Imc.EcStruct.MsgFun83Zone0MsgReg5 = 0; /*AC3 threshold in Celsius, 0xFF is not define */
- FchParams->Imc.EcStruct.MsgFun83Zone0MsgReg6 = 0; /*AC4 threshold in Celsius, 0xFF is not define */
- FchParams->Imc.EcStruct.MsgFun83Zone0MsgReg7 = 0; /*AC5 threshold in Celsius, 0xFF is not define */
- FchParams->Imc.EcStruct.MsgFun83Zone0MsgReg8 = 0; /*AC6 threshold in Celsius, 0xFF is not define */
- FchParams->Imc.EcStruct.MsgFun83Zone0MsgReg9 = 0; /*AC7 lowest threshold in Celsius, 0xFF is not define */
- FchParams->Imc.EcStruct.MsgFun83Zone0MsgRegA = 0; /*critical threshold* in Celsius, 0xFF is not define */
- FchParams->Imc.EcStruct.MsgFun83Zone0MsgRegB = 0x00;
-
- /* IMC Fan Policy PWM Settings */
- FchParams->Imc.EcStruct.MsgFun85Zone0MsgReg0 = 0x00;
- FchParams->Imc.EcStruct.MsgFun85Zone0MsgReg1 = 0x00; /* Zone */
- FchParams->Imc.EcStruct.MsgFun85Zone0MsgReg2 = 0; /* AL0 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone0MsgReg3 = 0; /* AL1 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone0MsgReg4 = 0; /* AL2 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone0MsgReg5 = 0x00; /* AL3 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone0MsgReg6 = 0x00; /* AL4 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone0MsgReg7 = 0x00; /* AL5 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone0MsgReg8 = 0x00; /* AL6 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone0MsgReg9 = 0x00; /* AL7 percentage */
-
- FchParams->Imc.EcStruct.MsgFun81Zone1MsgReg0 = 0x00;
- FchParams->Imc.EcStruct.MsgFun81Zone1MsgReg1 = 0x01; /* Zone */
- FchParams->Imc.EcStruct.MsgFun81Zone1MsgReg2 = 0x55;//BIT0 | BIT2 | BIT5;
- FchParams->Imc.EcStruct.MsgFun81Zone1MsgReg3 = 0x17;
- FchParams->Imc.EcStruct.MsgFun81Zone1MsgReg4 = 0x00;
- FchParams->Imc.EcStruct.MsgFun81Zone1MsgReg5 = 0x00;
- FchParams->Imc.EcStruct.MsgFun81Zone1MsgReg6 = 0x90; /* SMBUS Address for SMBUS based temperature sensor such as SB-TSI and ADM1032 */
- FchParams->Imc.EcStruct.MsgFun81Zone1MsgReg7 = 0;
- FchParams->Imc.EcStruct.MsgFun81Zone1MsgReg8 = 0; /* PWM steping rate in unit of PWM level percentage */
- FchParams->Imc.EcStruct.MsgFun81Zone1MsgReg9 = 0;
-
- FchParams->Imc.EcStruct.MsgFun83Zone1MsgReg0 = 0x00;
- FchParams->Imc.EcStruct.MsgFun83Zone1MsgReg1 = 0x01; /* zone */
- FchParams->Imc.EcStruct.MsgFun83Zone1MsgReg2 = 60; /*AC0 threshold in Celsius */
- FchParams->Imc.EcStruct.MsgFun83Zone1MsgReg3 = 40; /*AC1 threshold in Celsius */
- FchParams->Imc.EcStruct.MsgFun83Zone1MsgReg4 = 0; /*AC2 threshold in Celsius */
- FchParams->Imc.EcStruct.MsgFun83Zone1MsgReg5 = 0; /*AC3 threshold in Celsius, 0xFF is not define */
- FchParams->Imc.EcStruct.MsgFun83Zone1MsgReg6 = 0; /*AC4 threshold in Celsius, 0xFF is not define */
- FchParams->Imc.EcStruct.MsgFun83Zone1MsgReg7 = 0; /*AC5 threshold in Celsius, 0xFF is not define */
- FchParams->Imc.EcStruct.MsgFun83Zone1MsgReg8 = 0; /*AC6 threshold in Celsius, 0xFF is not define */
- FchParams->Imc.EcStruct.MsgFun83Zone1MsgReg9 = 0; /*AC7 lowest threshold in Celsius, 0xFF is not define */
- FchParams->Imc.EcStruct.MsgFun83Zone1MsgRegA = 0; /*critical threshold* in Celsius, 0xFF is not define */
- FchParams->Imc.EcStruct.MsgFun83Zone1MsgRegB = 0x00;
-
- FchParams->Imc.EcStruct.MsgFun85Zone1MsgReg0 = 0x00;
- FchParams->Imc.EcStruct.MsgFun85Zone1MsgReg1 = 0x01; /*Zone */
- FchParams->Imc.EcStruct.MsgFun85Zone1MsgReg2 = 0; /* AL0 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone1MsgReg3 = 0; /* AL1 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone1MsgReg4 = 0; /* AL2 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone1MsgReg5 = 0x00; /* AL3 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone1MsgReg6 = 0x00; /* AL4 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone1MsgReg7 = 0x00; /* AL5 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone1MsgReg8 = 0x00; /* AL6 percentage */
- FchParams->Imc.EcStruct.MsgFun85Zone1MsgReg9 = 0x00; /* AL7 percentage */
-
- FchParams->Imc.EcStruct.MsgFun81Zone2MsgReg0 = 0x00;
- FchParams->Imc.EcStruct.MsgFun81Zone2MsgReg1 = 0x2; /* Zone */
- FchParams->Imc.EcStruct.MsgFun81Zone2MsgReg2 = 0x0;//BIT0 | BIT2 | BIT5;
- FchParams->Imc.EcStruct.MsgFun81Zone2MsgReg3 = 0x0;
- FchParams->Imc.EcStruct.MsgFun81Zone2MsgReg4 = 0x00;
- FchParams->Imc.EcStruct.MsgFun81Zone2MsgReg5 = 0x00;
- FchParams->Imc.EcStruct.MsgFun81Zone2MsgReg6 = 0x98; /* SMBUS Address for SMBUS based temperature sensor such as SB-TSI and ADM1032 */
- FchParams->Imc.EcStruct.MsgFun81Zone2MsgReg7 = 2;
- FchParams->Imc.EcStruct.MsgFun81Zone2MsgReg8 = 5; /* PWM steping rate in unit of PWM level percentage */
- FchParams->Imc.EcStruct.MsgFun81Zone2MsgReg9 = 0;
-
- FchParams->Imc.EcStruct.MsgFun81Zone3MsgReg0 = 0x00;
- FchParams->Imc.EcStruct.MsgFun81Zone3MsgReg1 = 0x3; /* Zone */
- FchParams->Imc.EcStruct.MsgFun81Zone3MsgReg2 = 0x0;//BIT0 | BIT2 | BIT5;
- FchParams->Imc.EcStruct.MsgFun81Zone3MsgReg3 = 0x0;
- FchParams->Imc.EcStruct.MsgFun81Zone3MsgReg4 = 0x00;
- FchParams->Imc.EcStruct.MsgFun81Zone3MsgReg5 = 0x00;
- FchParams->Imc.EcStruct.MsgFun81Zone3MsgReg6 = 0x0; /* SMBUS Address for SMBUS based temperature sensor such as SB-TSI and ADM1032 */
- FchParams->Imc.EcStruct.MsgFun81Zone3MsgReg7 = 0;
- FchParams->Imc.EcStruct.MsgFun81Zone3MsgReg8 = 0; /* PWM steping rate in unit of PWM level percentage */
- FchParams->Imc.EcStruct.MsgFun81Zone3MsgReg9 = 0;
-
- /* IMC Function */
- FchParams->Imc.EcStruct.IMCFUNSupportBitMap = 0x333;//BIT0 | BIT4 |BIT8;
-
- /* NOTE:
- * FchInitLateHwm will overwrite the EcStruct with EcDefaultMassege,
- * AGESA put EcDefaultMassege as global data in ROM, so we can't overwride it.
- * so we remove it from AGESA code. Please Seee FchInitLateHwm.
- */
- } else {
- /* HWM fan control, the way not recommand */
- FchParams->Imc.ImcEnable = FALSE;
- FchParams->Hwm.HwMonitorEnable = TRUE;
- FchParams->Hwm.HwmFchtsiAutoPoll = TRUE;/* 1 enable, 0 disable TSI Auto Polling */
- }
-}
-#endif
-
-
void board_FCH_InitReset(struct sysinfo *cb_NA, FCH_RESET_DATA_BLOCK *FchParams_reset)
{
}
@@ -296,7 +118,4 @@ void board_FCH_InitEnv(struct sysinfo *cb_NA, FCH_DATA_BLOCK *FchParams_env)
{
/* Azalia Controller OEM Cqodec Table Pointer */
FchParams_env->Azalia.AzaliaOemCodecTablePtr = (CODEC_TBL_LIST*)CodecTableList;
-
- /* Fan Control */
- //oem_fan_control(FchParams_env);
}