1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
|
chip northbridge/amd/amdfam10/root_complex # Root complex
device cpu_cluster 0 on # (L)APIC cluster
chip cpu/amd/socket_F_1207 # CPU socket
device lapic 0 on end # Local APIC of the CPU
end
end
device domain 0 on # PCI domain
subsystemid 0x1043 0x8163 inherit
chip northbridge/amd/amdfam10 # Northbridge / RAM controller
register "maximum_memory_capacity" = "0x2000000000" # 128GB
device pci 18.0 on end # Link 0 == LDT 0
device pci 18.0 on end # Link 1 == LDT 1
device pci 18.0 on # Link 2 == LDT 2 [SB on link 2]
chip southbridge/amd/sr5650 # Primary southbridge
device pci 0.0 on end # HT Root Complex 0x9600
device pci 0.1 on end # CLKCONFIG
device pci 0.2 on end # IOMMU
device pci 2.0 on # PCIE P2P bridge 0x9603 (GPP1 Port0)
# Slot # PCI E 1 / PCI E 2
end
device pci 3.0 off end # PCIE P2P bridge 0x960b (GPP1 Port1)
device pci 4.0 on # PCIE P2P bridge 0x9604 (GPP3a Port0)
# PIKE SAS
end
device pci 5.0 off end # PCIE P2P bridge 0x9605 (GPP3a Port1)
device pci 6.0 off end # PCIE P2P bridge 0x9606 (GPP3a Port2)
device pci 7.0 off end # PCIE P2P bridge 0x9607 (GPP3a Port3)
device pci 8.0 off end # NB/SB Link P2P bridge
device pci 9.0 on # Bridge (GPP3a Port4)
# Onboard # NIC A
end
device pci a.0 on # Bridge (GPP3a Port5)
# Onboard # NIC B
end
device pci b.0 on # Bridge (GPP2 Port0)
# Slot # PCI E 4
end
register "gpp1_configuration" = "0" # Configuration 16:0 default
register "gpp2_configuration" = "1" # Configuration 8:8
register "gpp3a_configuration" = "2" # Configuration 4:1:1:0:0:0
register "port_enable" = "0x0f1c" # Enable all ports except 0, 1, 5, 6, and 7
register "pcie_settling_time" = "1000000" # Allow PIKE to be detected / configured
end
chip southbridge/amd/sb700 # Secondary southbridge
device pci 11.0 on end # SATA
device pci 12.0 on end # USB
device pci 12.1 on end # USB
device pci 12.2 on end # USB
device pci 13.0 on end # USB
device pci 13.1 on end # USB
device pci 13.2 on end # USB
device pci 14.0 on # SM
chip drivers/generic/generic # DIMM n-0-0-0
device i2c 50 on end
end
chip drivers/generic/generic # DIMM n-0-0-1
device i2c 51 on end
end
chip drivers/generic/generic # DIMM n-0-1-0
device i2c 52 on end
end
chip drivers/generic/generic # DIMM n-0-1-1
device i2c 53 on end
end
chip drivers/generic/generic # DIMM n-1-0-0
device i2c 54 on end
end
chip drivers/generic/generic # DIMM n-1-0-1
device i2c 55 on end
end
chip drivers/generic/generic # DIMM n-1-1-0
device i2c 56 on end
end
chip drivers/generic/generic # DIMM n-1-1-1
device i2c 57 on end
end
chip drivers/i2c/w83795
register "fanin_ctl1" = "0xff" # Enable monitoring of FANIN1 - FANIN8
register "fanin_ctl2" = "0x00" # Connect FANIN11 - FANIN14 to alternate functions
register "temp_ctl1" = "0x2a" # Enable monitoring of DTS, VSEN12, and VSEN13
register "temp_ctl2" = "0x01" # Enable monitoring of TD1/TR1
register "temp_dtse" = "0x03" # Enable DTS1 and DTS2
register "volt_ctl1" = "0xff" # Enable monitoring of VSEN1 - VSEN8
register "volt_ctl2" = "0xf7" # Enable monitoring of VSEN9 - VSEN11, 3VDD, 3VSB, and VBAT
register "temp1_fan_select" = "0x00" # All fans to manual mode (no dependence on Temp1)
register "temp2_fan_select" = "0x00" # All fans to manual mode (no dependence on Temp2)
register "temp3_fan_select" = "0x00" # All fans to manual mode (no dependence on Temp3)
register "temp4_fan_select" = "0x00" # All fans to manual mode (no dependence on Temp4)
register "temp5_fan_select" = "0x00" # All fans to manual mode (no dependence on Temp5)
register "temp6_fan_select" = "0x00" # All fans to manual mode (no dependence on Temp6)
register "temp1_source_select" = "0x00" # Use TD1/TR1 as data source for Temp1
register "temp2_source_select" = "0x00" # Use TD2/TR2 as data source for Temp2
register "temp3_source_select" = "0x00" # Use TD3/TR3 as data source for Temp3
register "temp4_source_select" = "0x00" # Use TD4/TR4 as data source for Temp4
register "temp5_source_select" = "0x00" # Use TR5 as data source for Temp5
register "temp6_source_select" = "0x00" # Use TR6 as data source for Temp6
register "tr1_critical_temperature" = "85" # Set TD1/TR1 critical temperature to 85°C
register "tr1_critical_hysteresis" = "80" # Set TD1/TR1 critical hysteresis temperature to 80°C
register "tr1_warning_temperature" = "70" # Set TD1/TR1 warning temperature to 70°C
register "tr1_warning_hysteresis" = "65" # Set TD1/TR1 warning hysteresis temperature to 65°C
register "dts_critical_temperature" = "85" # Set DTS (CPU) critical temperature to 85°C
register "dts_critical_hysteresis" = "80" # Set DTS (CPU) critical hysteresis temperature to 80°C
register "dts_warning_temperature" = "70" # Set DTS (CPU) warning temperature to 70°C
register "dts_warning_hysteresis" = "65" # Set DTS (CPU) warning hysteresis temperature to 65°C
register "temp1_critical_temperature" = "80" # Set Temp1 critical temperature to 80°C
register "temp2_critical_temperature" = "80" # Set Temp1 critical temperature to 80°C
register "temp3_critical_temperature" = "80" # Set Temp1 critical temperature to 80°C
register "temp4_critical_temperature" = "80" # Set Temp1 critical temperature to 80°C
register "temp5_critical_temperature" = "80" # Set Temp1 critical temperature to 80°C
register "temp6_critical_temperature" = "80" # Set Temp1 critical temperature to 80°C
register "temp1_target_temperature" = "80" # Set Temp1 target temperature to 80°C
register "temp2_target_temperature" = "80" # Set Temp1 target temperature to 80°C
register "temp3_target_temperature" = "80" # Set Temp1 target temperature to 80°C
register "temp4_target_temperature" = "80" # Set Temp1 target temperature to 80°C
register "temp5_target_temperature" = "80" # Set Temp1 target temperature to 80°C
register "temp6_target_temperature" = "80" # Set Temp1 target temperature to 80°C
register "fan1_nonstop" = "7" # Set Fan 1 minimum speed
register "fan2_nonstop" = "7" # Set Fan 2 minimum speed
register "fan3_nonstop" = "7" # Set Fan 3 minimum speed
register "fan4_nonstop" = "7" # Set Fan 4 minimum speed
register "fan5_nonstop" = "7" # Set Fan 5 minimum speed
register "fan6_nonstop" = "7" # Set Fan 6 minimum speed
register "fan7_nonstop" = "7" # Set Fan 7 minimum speed
register "fan8_nonstop" = "7" # Set Fan 8 minimum speed
register "default_speed" = "100" # All fans to full speed on power up
register "fan1_duty" = "100" # Fan 1 to full speed
register "fan2_duty" = "100" # Fan 2 to full speed
register "fan3_duty" = "100" # Fan 3 to full speed
register "fan4_duty" = "100" # Fan 4 to full speed
register "fan5_duty" = "100" # Fan 5 to full speed
register "fan6_duty" = "100" # Fan 6 to full speed
register "fan7_duty" = "100" # Fan 7 to full speed
register "fan8_duty" = "100" # Fan 8 to full speed
register "vcore1_high_limit_mv" = "1500" # VCORE1 (Node 0) high limit to 1.5V
register "vcore1_low_limit_mv" = "900" # VCORE1 (Node 0) low limit to 0.9V
register "vcore2_high_limit_mv" = "1500" # VCORE2 (Node 1) high limit to 1.5V
register "vcore2_low_limit_mv" = "900" # VCORE2 (Node 1) low limit to 0.9V
register "vsen3_high_limit_mv" = "1600" # VSEN1 (Node 0 RAM voltage) high limit to 1.6V
register "vsen3_low_limit_mv" = "1100" # VSEN1 (Node 0 RAM voltage) low limit to 1.1V
register "vsen4_high_limit_mv" = "1600" # VSEN2 (Node 1 RAM voltage) high limit to 1.6V
register "vsen4_low_limit_mv" = "1100" # VSEN2 (Node 1 RAM voltage) low limit to 1.1V
register "vsen5_high_limit_mv" = "1250" # VSEN5 (Node 0 HT link voltage) high limit to 1.25V
register "vsen5_low_limit_mv" = "1150" # VSEN5 (Node 0 HT link voltage) low limit to 1.15V
register "vsen6_high_limit_mv" = "1250" # VSEN6 (Node 1 HT link voltage) high limit to 1.25V
register "vsen6_low_limit_mv" = "1150" # VSEN6 (Node 1 HT link voltage) low limit to 1.15V
register "vsen7_high_limit_mv" = "1150" # VSEN7 (Northbridge core voltage) high limit to 1.15V
register "vsen7_low_limit_mv" = "1050" # VSEN7 (Northbridge core voltage) low limit to 1.05V
register "vsen8_high_limit_mv" = "1900" # VSEN8 (+1.8V) high limit to 1.9V
register "vsen8_low_limit_mv" = "1700" # VSEN8 (+1.8V) low limit to 1.7V
register "vsen9_high_limit_mv" = "1250" # VSEN9 (+1.2V) high limit to 1.25V
register "vsen9_low_limit_mv" = "1150" # VSEN9 (+1.2V) low limit to 1.15V
register "vsen10_high_limit_mv" = "1150" # VSEN10 (+1.1V) high limit to 1.15V
register "vsen10_low_limit_mv" = "1050" # VSEN10 (+1.1V) low limit to 1.05V
register "vsen11_high_limit_mv" = "1625" # VSEN11 (5VSB, scaling factor ~3.2) high limit to 5.2V
register "vsen11_low_limit_mv" = "1500" # VSEN11 (5VSB, scaling factor ~3.2) low limit to 4.8V
register "vsen12_high_limit_mv" = "1083" # VSEN12 (+12V, scaling factor ~12) high limit to 13V
register "vsen12_low_limit_mv" = "917" # VSEN12 (+12V, scaling factor ~12) low limit to 11V
register "vsen13_high_limit_mv" = "1625" # VSEN13 (+5V, scaling factor ~3.2) high limit to 5.2V
register "vsen13_low_limit_mv" = "1500" # VSEN13 (+5V, scaling factor ~3.2) low limit to 4.8V
register "vdd_high_limit_mv" = "3500" # 3VDD high limit to 3.5V
register "vdd_low_limit_mv" = "3100" # 3VDD low limit to 3.1V
register "vsb_high_limit_mv" = "3500" # 3VSB high limit to 3.5V
register "vsb_low_limit_mv" = "3100" # 3VSB low limit to 3.1V
register "vbat_high_limit_mv" = "3500" # VBAT (+3V) high limit to 3.5V
register "vbat_low_limit_mv" = "2500" # VBAT (+3V) low limit to 2.5V
register "smbus_aux" = "1" # Device located on auxiliary SMBUS controller
device i2c 0x2f on end
end
end
device pci 14.1 on end # IDE 0x439c
device pci 14.2 on end # HDA 0x4383 (ASUS MIO add-on card)
device pci 14.3 on # LPC 0x439d (SMBUS primary controller)
chip superio/winbond/w83667hg-a # Super I/O
device pnp 2e.0 off end # FDC; Not available on the KCMA-D8
device pnp 2e.1 off end # LPT1; Not available on the KCMA-D8
device pnp 2e.2 on # COM1
io 0x60 = 0x3f8
irq 0x70 = 4
end
device pnp 2e.3 on # COM2
io 0x60 = 0x2f8
irq 0x70 = 3
end
device pnp 2e.5 on # PS/2 keyboard & mouse
io 0x60 = 0x60
io 0x62 = 0x64
irq 0x70 = 1
irq 0x72 = 12
end
device pnp 2e.106 off end # SPI: Not available on the KCMA-D8
device pnp 2e.107 off end # GIPO6
device pnp 2e.207 off end # GIPO7
device pnp 2e.307 off end # GIPO8
device pnp 2e.407 off end # GIPO9
device pnp 2e.8 off end # WDT
device pnp 2e.108 off end # GPIO 1
device pnp 2e.9 off end # GPIO2
device pnp 2e.109 off end # GPIO3
device pnp 2e.209 off end # GPIO4
device pnp 2e.309 off end # GPIO5
device pnp 2e.a on end # ACPI
device pnp 2e.b on # HW Monitor
io 0x60 = 0x290
# IRQ purposefully not assigned to prevent lockups
end
device pnp 2e.c off end # PECI
device pnp 2e.d off end # VID_BUSSEL
device pnp 2e.f off end # GPIO_PP_OD
end
end
device pci 14.4 on # Bridge
device pci 1.0 on # Slot
# Slot # PCI 0
end
device pci 2.0 on # Slot
# Slot # PCI 1
end
device pci 3.0 on # Slot
# Slot # PCI 2
end
device pci 5.0 on end # VGA
end
device pci 14.5 on end # USB OHCI2 0x4399
end
end
device pci 18.1 on end
device pci 18.2 on end
device pci 18.3 on end
device pci 18.4 on end
device pci 18.5 on end
device pci 19.0 on end # Socket 1 node 0
device pci 19.1 on end
device pci 19.2 on end
device pci 19.3 on end
device pci 19.4 on end
device pci 19.5 on end
end
end
end
|