//** (C)Copyright 1985-2009, American Megatrends, Inc. **
//** **
//** All Rights Reserved. **
//** **
//** 5555 Oakbrook Pkwy, Norcross, GA 30093 **
//** **
//** Phone: (770)-246-8600 **
//** **
//**********************************************************************
//**********************************************************************
// $Header: /Alaska/BIN/Modules/ACPI/Template/Core/SMB_EC.ASL 2 3/26/09 4:53p Oleksiyy $
//
// $Revision: 2 $
//
// $Date: 3/26/09 4:53p $
//**********************************************************************;
// Revision History
// ----------------
// $Log: /Alaska/BIN/Modules/ACPI/Template/Core/SMB_EC.ASL $
//
// 2 3/26/09 4:53p Oleksiyy
// New ACPI Core implementation - improves logic, execution time and
// memory usage of ACPI module.
//
// 1 3/24/05 5:01p Sivagarn
//
// 1 2/03/05 6:42p Sivagarn
// 0ABHI001 Check in
//
// 1 7/27/04 2:48p Yakovlevs
//
// 2 9/06/02 10:53a Alexp
// Add SourceSafe headers to all core asl files
//
//
//**********************************************************************;
//**********************************************************************;
// DON'T CHANGE ANY NAMES UNLESS REQUIRED !!!
//**********************************************************************;
// ACPI Embedded controller SMBus interface methods
//**********************************************************************;
// SMBR - SMBus read method
//
// Arg0 - Device address
// Arg1 - Command Code
// Arg2 - Data to write
// Arg3 - Protocol (basically RDWD, WRWD or RDBL)
Method(SMBR,4) {
If (LEqual(Arg3,RDBL)) {Store(0,DATB)}
Store(5, Local0)
While(Local0) {
Store(Arg0, ADDR) // Set the device address
Store(Arg1, SCMD) // Read Power unit value 0x3 offset
If (LEqual(Arg3, WRWD)) {Store(Arg2, DAT0)}
Store(Arg3, PRTC) // Set protocol - start SMBus transaction
Wait(SMBF, 0xFFF) // Wait till SMBus transaction completed
Reset(SMBF)
// One of known problems - ReadBlock of GLW SmartBattery may return BCNT=3
// and data as FF FF FF with no any SMBus errors. To avoid this:
// If(Or(SSTS,And(LEqual(Arg2,RDBL),And(LEqual(BCNT,3),LEqual(DAT0,0xFFFF)))))
If(SSTS)
{Decrement(Local0)} // If any SMBus error
Else {
Return(Ones) // exit on OK
}
}
Return(Zero) // exit on failure
}
//**********************************************************************;
// *****************************************************************;
// *****************************************************************;
// ** **;
// ** (C)Copyright 1985-1996, American Megatrends, Inc. **;
// ** **;
// ** All Rights Reserved. **;
// ** **;
// ** 6145-F Northbelt Pkwy, Norcross, GA 30071 **;
// ** **;
// ** Phone (770)-246-8600 **;
// ** **;
// *****************************************************************;
// *****************************************************************;
|