Age | Commit message (Collapse) | Author |
|
Change-Id: I6b03cc6f67e76dffb79940431711ae6171901c6a
Signed-off-by: Sean Wilson <spwilson2@wisc.edu>
Reviewed-on: https://gem5-review.googlesource.com/3748
Reviewed-by: Andreas Sandberg <andreas.sandberg@arm.com>
Maintainer: Andreas Sandberg <andreas.sandberg@arm.com>
|
|
Change-Id: I08de5f72513645d1fe92bde99fa205dde897e951
Signed-off-by: Sean Wilson <spwilson2@wisc.edu>
Reviewed-on: https://gem5-review.googlesource.com/3747
Reviewed-by: Jason Lowe-Power <jason@lowepower.com>
Reviewed-by: Anthony Gutierrez <anthony.gutierrez@amd.com>
Reviewed-by: Andreas Sandberg <andreas.sandberg@arm.com>
Maintainer: Andreas Sandberg <andreas.sandberg@arm.com>
|
|
Fixing an issue with regStats not calling the parent class method
for most SimObjects in Gem5. This causes issues if one adds new
stats in the base class (since they are never initialized properly!).
Change-Id: Iebc5aa66f58816ef4295dc8e48a357558d76a77c
Reviewed-by: Andreas Sandberg <andreas.sandberg@arm.com>
|
|
|
|
Add 4 power states to the ClockedObject, provides necessary access functions
to check and update the power state. Default power state is UNDEFINED, it is
responsibility of the respective simulation model to provide the startup state
and any other logic for state change.
Add number of transition stat.
Add distribution of time spent in clock gated state.
Add power state residency stat.
Add dump call back function to allow stats update of distribution and residency
stats.
|
|
Result of running 'hg m5style --skip-all --fix-control -a'.
|
|
This patch fixes the drain logic for the UFSHostDevice and the
FlashDevice. In the case of the FlashDevice, the logic for CheckDrain
needed to be reversed, whilst in the case of the UFSHostDevice check
drain was never being called. In both cases the system would never
complete draining if the initial attampt to drain failed.
|
|
The drain() call currently passes around a DrainManager pointer, which
is now completely pointless since there is only ever one global
DrainManager in the system. It also contains vestiges from the time
when SimObjects had to keep track of their child objects that needed
draining.
This changeset moves all of the DrainState handling to the Drainable
base class and changes the drain() and drainResume() calls to reflect
this. Particularly, the drain() call has been updated to take no
parameters (the DrainManager argument isn't needed) and return a
DrainState instead of an unsigned integer (there is no point returning
anything other than 0 or 1 any more). Drainable objects should return
either DrainState::Draining (equivalent to returning 1 in the old
system) if they need more time to drain or DrainState::Drained
(equivalent to returning 0 in the old system) if they are already in a
consistent state. Returning DrainState::Running is considered an
error.
Drain done signalling is now done through the signalDrainDone() method
in the Drainable class instead of using the DrainManager directly. The
new call checks if the state of the object is DrainState::Draining
before notifying the drain manager. This means that it is safe to call
signalDrainDone() without first checking if the simulator has
requested draining. The intention here is to reduce the code needed to
implement draining in simple objects.
|
|
Draining is currently done by traversing the SimObject graph and
calling drain()/drainResume() on the SimObjects. This is not ideal
when non-SimObjects (e.g., ports) need draining since this means that
SimObjects owning those objects need to be aware of this.
This changeset moves the responsibility for finding objects that need
draining from SimObjects and the Python-side of the simulator to the
DrainManager. The DrainManager now maintains a set of all objects that
need draining. To reduce the overhead in classes owning non-SimObjects
that need draining, objects inheriting from Drainable now
automatically register with the DrainManager. If such an object is
destroyed, it is automatically unregistered. This means that drain()
and drainResume() should never be called directly on a Drainable
object.
While implementing the new functionality, the DrainManager has now
been made thread safe. In practice, this means that it takes a lock
whenever it manipulates the set of Drainable objects since SimObjects
in different threads may create Drainable objects
dynamically. Similarly, the drain counter is now an atomic_uint, which
ensures that it is manipulated correctly when objects signal that they
are done draining.
A nice side effect of these changes is that it makes the drain state
changes stricter, which the simulation scripts can exploit to avoid
redundant drains.
|
|
The drain state enum is currently a part of the Drainable
interface. The same state machine will be used by the DrainManager to
identify the global state of the simulator. Make the drain state a
global typed enum to better cater for this usage scenario.
|
|
Objects that are can be serialized are supposed to inherit from the
Serializable class. This class is meant to provide a unified API for
such objects. However, so far it has mainly been used by SimObjects
due to some fundamental design limitations. This changeset redesigns
to the serialization interface to make it more generic and hide the
underlying checkpoint storage. Specifically:
* Add a set of APIs to serialize into a subsection of the current
object. Previously, objects that needed this functionality would
use ad-hoc solutions using nameOut() and section name
generation. In the new world, an object that implements the
interface has the methods serializeSection() and
unserializeSection() that serialize into a named /subsection/ of
the current object. Calling serialize() serializes an object into
the current section.
* Move the name() method from Serializable to SimObject as it is no
longer needed for serialization. The fully qualified section name
is generated by the main serialization code on the fly as objects
serialize sub-objects.
* Add a scoped ScopedCheckpointSection helper class. Some objects
need to serialize data structures, that are not deriving from
Serializable, into subsections. Previously, this was done using
nameOut() and manual section name generation. To simplify this,
this changeset introduces a ScopedCheckpointSection() helper
class. When this class is instantiated, it adds a new /subsection/
and subsequent serialization calls during the lifetime of this
helper class happen inside this section (or a subsection in case
of nested sections).
* The serialize() call is now const which prevents accidental state
manipulation during serialization. Objects that rely on modifying
state can use the serializeOld() call instead. The default
implementation simply calls serialize(). Note: The old-style calls
need to be explicitly called using the
serializeOld()/serializeSectionOld() style APIs. These are used by
default when serializing SimObjects.
* Both the input and output checkpoints now use their own named
types. This hides underlying checkpoint implementation from
objects that need checkpointing and makes it easier to change the
underlying checkpoint storage code.
|
|
This patch introduces a UFS host controller and a UFS device. More
information about the UFS standard can be found at the JEDEC site:
http://www.jedec.org/standards-documents/results/jesd220
Note that the model does not implement the complete standard, and as
such is not an actual implementation of UFS. The following SCSI
commands are implemented: inquiry, read, read capacity, report LUNs,
start/stop, test unit ready, verify, write, format unit, send
diagnostic, synchronize cache, mode select, mode sense, request sense,
unmap, write buffer and read buffer. This is sufficient for usage with
Linux and Android.
To interact with this model a kernel version 3.9 or above is
needed.
|